Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category3
Pollution degree3
Voltage typeOther
Rated voltage240V
Frequency50 - 60Hz
Rated current10A
Rated insulation voltage Ui440V
Current limiting class3
Built-in depth75mm
Release characteristicK
Width in number of modular spacings2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Number of protected poles2
Explosion-proofNo
Concurrently switching neutral conductorNo
Number of poles (total)2
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Connectable conductor cross section solid-core0.75 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated impulse withstand voltage Uimp4kV
Degree of protection (IP)IP20
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Power loss3.2W

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS572001R0427 | S402M-K10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category

3

Pollution degree

3

Voltage type

Other

Rated voltage

240V

Frequency

50 .. 60Hz

Rated current

10A

Rated insulation voltage Ui

440V

Current limiting class

3

Built-in depth

75mm

Release characteristic

K

Width in number of modular spacings

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Number of protected poles

2

Explosion-proof

Concurrently switching neutral conductor

Number of poles (total)

2

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated impulse withstand voltage Uimp

4kV

Degree of protection (IP)

IP20

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Power loss

3.2W