Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth75mm
Rated current13A
Voltage typeOther
Rated insulation voltage Ui440V
Explosion-proofNo
Width in number of modular spacings2
Concurrently switching neutral conductorNo
Rated voltage240V
Release characteristicK
Frequency50 - 60Hz
Degree of protection (IP)IP20
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Power loss3.8W
Current limiting class3
Connectable conductor cross section solid-core0.75 - 35mm²
Rated impulse withstand voltage Uimp4kV
Pollution degree3
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Connectable conductor cross section multi-wired0.75 - 25mm²
Number of poles (total)2
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Over voltage category3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS572001R0447 | S402M-K13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

75mm

Rated current

13A

Voltage type

Other

Rated insulation voltage Ui

440V

Explosion-proof

Width in number of modular spacings

2

Concurrently switching neutral conductor

Rated voltage

240V

Release characteristic

K

Frequency

50 .. 60Hz

Degree of protection (IP)

IP20

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Power loss

3.8W

Current limiting class

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated impulse withstand voltage Uimp

4kV

Pollution degree

3

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Number of poles (total)

2

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Over voltage category

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.