Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth75mm
Voltage typeOther
Rated voltage240V
Over voltage category3
Rated current50A
Power loss7.6W
Release characteristicK
Explosion-proofNo
Pollution degree3
Width in number of modular spacings2
Current limiting class3
Frequency50 - 60Hz
Degree of protection (IP)IP20
Rated insulation voltage Ui440V
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Concurrently switching neutral conductorNo
Number of protected poles2
Number of poles (total)2
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated impulse withstand voltage Uimp4kV
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS572001R0577 | S402M-K50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

75mm

Voltage type

Other

Rated voltage

240V

Over voltage category

3

Rated current

50A

Power loss

7.6W

Release characteristic

K

Explosion-proof

Pollution degree

3

Width in number of modular spacings

2

Current limiting class

3

Frequency

50 .. 60Hz

Degree of protection (IP)

IP20

Rated insulation voltage Ui

440V

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Concurrently switching neutral conductor

Number of protected poles

2

Number of poles (total)

2

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated impulse withstand voltage Uimp

4kV

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA