Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Rated current3A
Built-in depth75mm
Rated voltage400V
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Release characteristicOther
Current limiting class3
Number of protected poles2
Width in number of modular spacings2
Pollution degree2
Degree of protection (IP)IP20
Over voltage category3
Concurrently switching neutral conductorNo
Number of poles (total)2
Power loss4.2W
Explosion-proofNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Connectable conductor cross section solid-core0.75 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section multi-wired0.75 - 25mm²
Additional equipment possibleYes
Flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS572001R1034 | S402M-UCC3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Rated current

3A

Built-in depth

75mm

Rated voltage

400V

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Release characteristic

Other

Current limiting class

3

Number of protected poles

2

Width in number of modular spacings

2

Pollution degree

2

Degree of protection (IP)

IP20

Over voltage category

3

Concurrently switching neutral conductor

Number of poles (total)

2

Power loss

4.2W

Explosion-proof

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA