Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current40A
Frequency50 - 60Hz
Rated voltage400V
Voltage typeOther
Built-in depth75mm
Explosion-proofNo
Over voltage category3
Power loss8.4W
Pollution degree2
Release characteristicOther
Current limiting class3
Number of protected poles2
Degree of protection (IP)IP20
Width in number of modular spacings2
Concurrently switching neutral conductorNo
Rated insulation voltage Ui440V
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated impulse withstand voltage Uimp4kV

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS572001R1408 | S402M-UCZ40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

40A

Frequency

50 .. 60Hz

Rated voltage

400V

Voltage type

Other

Built-in depth

75mm

Explosion-proof

Over voltage category

3

Power loss

8.4W

Pollution degree

2

Release characteristic

Other

Current limiting class

3

Number of protected poles

2

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Concurrently switching neutral conductor

Rated insulation voltage Ui

440V

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated impulse withstand voltage Uimp

4kV

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.