Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicB
Rated voltage400V
Frequency50 - 60Hz
Built-in depth75mm
Rated current6A
Current limiting class3
Rated insulation voltage Ui440V
Over voltage category3
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Ambient temperature during operating-25 - 60°C
Number of poles (total)3
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core0.75 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 25mm²
Explosion-proofNo
Additional equipment possibleYes
Number of protected poles3
Pollution degree3
Width in number of modular spacings3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Power loss5.4W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS573001R0065 | S403M-B6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Rated voltage

400V

Frequency

50 .. 60Hz

Built-in depth

75mm

Rated current

6A

Current limiting class

3

Rated insulation voltage Ui

440V

Over voltage category

3

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Ambient temperature during operating

-25 .. 60°C

Number of poles (total)

3

Flush-mounted installation

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Explosion-proof

Additional equipment possible

Number of protected poles

3

Pollution degree

3

Width in number of modular spacings

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Power loss

5.4W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.