Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth75mm
Rated current8A
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Current limiting class3
Frequency50 - 60Hz
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Number of poles (total)3
Pollution degree3
Release characteristicD
Over voltage category3
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Concurrently switching neutral conductorNo
Rated voltage400V
Power loss3.9W
Rated insulation voltage Ui440V
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0.75 - 35mm²
Number of protected poles3
Explosion-proofNo
Width in number of modular spacings3
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS573001R0081 | S403M-D8

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

75mm

Rated current

8A

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Current limiting class

3

Frequency

50 .. 60Hz

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Number of poles (total)

3

Pollution degree

3

Release characteristic

D

Over voltage category

3

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

Rated voltage

400V

Power loss

3.9W

Rated insulation voltage Ui

440V

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 .. 35mm²

Number of protected poles

3

Explosion-proof

Width in number of modular spacings

3

Rated impulse withstand voltage Uimp

4kV