Aleta.hr
Main Product Image

2CCS573001R0085 | S403M-B8

Code: 2002149

ManufacturerABB
Catalog number2CCS573001R0085
EAN code7612270108435

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth75mm
Release characteristicB
Number of poles (total)3
Number of protected poles3
Rated current8A
Rated voltage400V
Rated insulation voltage Ui440V
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Frequency50 - 60Hz
Power loss4.2W
Current limiting class3
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Over voltage category3
Pollution degree3
Additional equipment possibleYes
Width in number of modular spacings3
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS573001R0085 | S403M-B8

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

75mm

Release characteristic

B

Number of poles (total)

3

Number of protected poles

3

Rated current

8A

Rated voltage

400V

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Frequency

50 .. 60Hz

Power loss

4.2W

Current limiting class

3

Flush-mounted installation

Concurrently switching neutral conductor

Over voltage category

3

Pollution degree

3

Additional equipment possible

Width in number of modular spacings

3

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.