Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicD
Rated current10A
Rated voltage400V
Frequency50 - 60Hz
Voltage typeOther
Built-in depth75mm
Rated insulation voltage Ui440V
Explosion-proofNo
Current limiting class3
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0.75 - 35mm²
Width in number of modular spacings3
Over voltage category3
Power loss4.8W
Number of protected poles3
Pollution degree3
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Number of poles (total)3
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS573001R0101 | S403M-D10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

D

Rated current

10A

Rated voltage

400V

Frequency

50 .. 60Hz

Voltage type

Other

Built-in depth

75mm

Rated insulation voltage Ui

440V

Explosion-proof

Current limiting class

3

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 .. 35mm²

Width in number of modular spacings

3

Over voltage category

3

Power loss

4.8W

Number of protected poles

3

Pollution degree

3

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Number of poles (total)

3

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.