Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Width in number of modular spacings3
Pollution degree3
Built-in depth75mm
Explosion-proofNo
Current limiting class3
Over voltage category3
Voltage typeOther
Rated current2A
Release characteristicK
Rated voltage415V
Rated insulation voltage Ui440V
Number of protected poles3
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Flush-mounted installationNo
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Power loss3.9W
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS573001R0277 | S403M-K2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Width in number of modular spacings

3

Pollution degree

3

Built-in depth

75mm

Explosion-proof

Current limiting class

3

Over voltage category

3

Voltage type

Other

Rated current

2A

Release characteristic

K

Rated voltage

415V

Rated insulation voltage Ui

440V

Number of protected poles

3

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Flush-mounted installation

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Power loss

3.9W

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.