Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth75mm
Over voltage category3
Rated insulation voltage Ui440V
Width in number of modular spacings3
Degree of protection (IP)IP20
Pollution degree3
Explosion-proofNo
Frequency50 - 60Hz
Release characteristicC
Rated voltage415V
Current limiting class3
Voltage typeOther
Rated current40A
Power loss11.1W
Connectable conductor cross section multi-wired0.75 - 25mm²
Number of poles (total)3
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Ambient temperature during operating-25 - 60°C
Number of protected poles3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Connectable conductor cross section solid-core0.75 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS573001R0404 | S403M-C40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

75mm

Over voltage category

3

Rated insulation voltage Ui

440V

Width in number of modular spacings

3

Degree of protection (IP)

IP20

Pollution degree

3

Explosion-proof

Frequency

50 .. 60Hz

Release characteristic

C

Rated voltage

415V

Current limiting class

3

Voltage type

Other

Rated current

40A

Power loss

11.1W

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Number of poles (total)

3

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Ambient temperature during operating

-25 .. 60°C

Number of protected poles

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.