Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class3
Voltage typeOther
Pollution degree3
Frequency50 - 60Hz
Built-in depth75mm
Rated current10A
Width in number of modular spacings4
Rated voltage415V
Explosion-proofNo
Release characteristicC
Over voltage category3
Rated insulation voltage Ui440V
Power loss6.8W
Concurrently switching neutral conductorYes
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Number of protected poles4
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
Flush-mounted installationNo
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS573103R8104 | S403M-C10NP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Current limiting class

3

Voltage type

Other

Pollution degree

3

Frequency

50 .. 60Hz

Built-in depth

75mm

Rated current

10A

Width in number of modular spacings

4

Rated voltage

415V

Explosion-proof

Release characteristic

C

Over voltage category

3

Rated insulation voltage Ui

440V

Power loss

6.8W

Concurrently switching neutral conductor

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Number of protected poles

4

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Flush-mounted installation

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA