Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth75mm
Frequency50 - 60Hz
Explosion-proofNo
Rated voltage415V
Degree of protection (IP)IP20
Rated current1A
Current limiting class3
Flush-mounted installationNo
Number of protected poles4
Width in number of modular spacings4
Power loss4.4W
Connectable conductor cross section multi-wired0.75 - 25mm²
Over voltage category3
Pollution degree3
Concurrently switching neutral conductorYes
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Release characteristicK
Connectable conductor cross section solid-core0.75 - 35mm²
Voltage typeOther
Rated insulation voltage Ui440V
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS573103R8217 | S403M-K1NP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

75mm

Frequency

50 .. 60Hz

Explosion-proof

Rated voltage

415V

Degree of protection (IP)

IP20

Rated current

1A

Current limiting class

3

Flush-mounted installation

Number of protected poles

4

Width in number of modular spacings

4

Power loss

4.4W

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Over voltage category

3

Pollution degree

3

Concurrently switching neutral conductor

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Release characteristic

K

Connectable conductor cross section solid-core

0.75 .. 35mm²

Voltage type

Other

Rated insulation voltage Ui

440V

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.