Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Rated current40A
Built-in depth82.5mm
Rated voltage-V
Over voltage category3
Frequency0 - 0Hz
Additional equipment possibleYes
Rated insulation voltage Ui1500V
Current limiting class3
Explosion-proofNo
Concurrently switching neutral conductorNo
Pollution degree2
Connectable conductor cross section multi-wired0 - 50mm²
Connectable conductor cross section solid-core0 - 70mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Width in number of modular spacings3
Number of poles (total)2
Ambient temperature during operating-25 - 60°C
Release characteristicOther
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Power loss7.4W
Degree of protection (IP)IP20
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862002R1405 | S802S-UCB40-R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Rated current

40A

Built-in depth

82.5mm

Rated voltage

-V

Over voltage category

3

Frequency

0 .. 0Hz

Additional equipment possible

Rated insulation voltage Ui

1500V

Current limiting class

3

Explosion-proof

Concurrently switching neutral conductor

Pollution degree

2

Connectable conductor cross section multi-wired

0 .. 50mm²

Connectable conductor cross section solid-core

0 .. 70mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Width in number of modular spacings

3

Number of poles (total)

2

Ambient temperature during operating

-25 .. 60°C

Release characteristic

Other

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Power loss

7.4W

Degree of protection (IP)

IP20

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

8kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.