Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Current limiting class3
Release characteristicK
Over voltage category3
Frequency50 - 60Hz
Rated current50A
Pollution degree2
Explosion-proofNo
Rated insulation voltage Ui690V
Built-in depth82.5mm
Width in number of modular spacings3
Rated voltage-V
Number of protected poles2
Degree of protection (IP)IP20
Power loss4.3W
Flush-mounted installationNo
Connectable conductor cross section multi-wired0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Concurrently switching neutral conductorNo
Rated impulse withstand voltage Uimp8kV
Number of poles (total)2
Connectable conductor cross section solid-core0 - 70mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862017R0577 | S802U-K50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Current limiting class

3

Release characteristic

K

Over voltage category

3

Frequency

50 .. 60Hz

Rated current

50A

Pollution degree

2

Explosion-proof

Rated insulation voltage Ui

690V

Built-in depth

82.5mm

Width in number of modular spacings

3

Rated voltage

-V

Number of protected poles

2

Degree of protection (IP)

IP20

Power loss

4.3W

Flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

8kV

Number of poles (total)

2

Connectable conductor cross section solid-core

0 .. 70mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.