Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Over voltage category3
Concurrently switching neutral conductorNo
Rated voltage-V
Rated current80A
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Built-in depth82.5mm
Rated insulation voltage Ui690V
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Number of protected poles2
Release characteristicK
Flush-mounted installationNo
Power loss6.4W
Connectable conductor cross section multi-wired0 - 50mm²
Pollution degree2
Connectable conductor cross section solid-core0 - 70mm²
Number of poles (total)2
Current limiting class3
Frequency50 - 60Hz
Explosion-proofNo
Width in number of modular spacings3
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated impulse withstand voltage Uimp8kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862017R0627 | S802U-K80

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Over voltage category

3

Concurrently switching neutral conductor

Rated voltage

-V

Rated current

80A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

82.5mm

Rated insulation voltage Ui

690V

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Number of protected poles

2

Release characteristic

K

Flush-mounted installation

Power loss

6.4W

Connectable conductor cross section multi-wired

0 .. 50mm²

Pollution degree

2

Connectable conductor cross section solid-core

0 .. 70mm²

Number of poles (total)

2

Current limiting class

3

Frequency

50 .. 60Hz

Explosion-proof

Width in number of modular spacings

3

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

8kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.