Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Rated impulse withstand voltage Uimp8kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Number of poles (total)2
Current limiting class3
Power loss6.5W
Rated insulation voltage Ui690V
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Rated current90A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated voltage-V
Built-in depth82.5mm
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Release characteristicK
Degree of protection (IP)IP20
Over voltage category3
Concurrently switching neutral conductorNo
Pollution degree2
Ambient temperature during operating-25 - 60°C
Flush-mounted installationNo
Width in number of modular spacings3
Explosion-proofNo
Connectable conductor cross section multi-wired0 - 50mm²
Connectable conductor cross section solid-core0 - 70mm²
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS862017R0907 | S802U-K90

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of poles (total)

2

Current limiting class

3

Power loss

6.5W

Rated insulation voltage Ui

690V

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated current

90A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated voltage

-V

Built-in depth

82.5mm

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Release characteristic

K

Degree of protection (IP)

IP20

Over voltage category

3

Concurrently switching neutral conductor

Pollution degree

2

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Width in number of modular spacings

3

Explosion-proof

Connectable conductor cross section multi-wired

0 .. 50mm²

Connectable conductor cross section solid-core

0 .. 70mm²

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.