Aleta.hr
Main Product Image

2CCS863017R0457 | S803U-K15

Code: 2002282

ManufacturerRAZNO
Catalog number2CCS863017R0457
Type
EAN code7612271214067

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Rated current

15A

Number of poles (total)

3

Number of protected poles

3

Release characteristic

K

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated insulation voltage Ui

690V

Current limiting class

3

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated voltage

-V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

8kV

Power loss

2.7W

Flush-mounted installation

No

Width in number of modular spacings

4.5

Pollution degree

2

Over voltage category

3

Connectable conductor cross section multi-wired

0 - 50mm²

Ambient temperature during operating

-25 - 60°C

Additional equipment possible

Yes

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

No

Connectable conductor cross section solid-core

0 - 70mm²

Explosion-proof

No


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCS863017R0457 | S803U-K15

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Rated current

15A

Number of poles (total)

3

Number of protected poles

3

Release characteristic

K

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated insulation voltage Ui

690V

Current limiting class

3

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated voltage

-V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

8kV

Power loss

2.7W

Flush-mounted installation

Width in number of modular spacings

4.5

Pollution degree

2

Over voltage category

3

Connectable conductor cross section multi-wired

0 .. 50mm²

Ambient temperature during operating

-25 .. 60°C

Additional equipment possible

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0 .. 70mm²

Explosion-proof

From same serie