Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)3
Rated voltage-V
Rated current90A
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated insulation voltage Ui690V
Rated impulse withstand voltage Uimp8kV
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V50kA
Current limiting class3
Release characteristicK
Built-in depth82.5mm
Frequency50 - 60Hz
Power loss6.5W
Number of protected poles3
Pollution degree2
Flush-mounted installationNo
Additional equipment possibleYes
Width in number of modular spacings4.5
Ambient temperature during operating-25 - 60°C
Over voltage category3
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0 - 70mm²
Explosion-proofNo
Connectable conductor cross section multi-wired0 - 50mm²
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS863017R0907 | S803U-K90

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

3

Rated voltage

-V

Rated current

90A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated insulation voltage Ui

690V

Rated impulse withstand voltage Uimp

8kV

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Current limiting class

3

Release characteristic

K

Built-in depth

82.5mm

Frequency

50 .. 60Hz

Power loss

6.5W

Number of protected poles

3

Pollution degree

2

Flush-mounted installation

Additional equipment possible

Width in number of modular spacings

4.5

Ambient temperature during operating

-25 .. 60°C

Over voltage category

3

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0 .. 70mm²

Explosion-proof

Connectable conductor cross section multi-wired

0 .. 50mm²

Concurrently switching neutral conductor

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.