Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth82.5mm
Rated current63A
Voltage typeOther
Rated insulation voltage Ui1500V
Current limiting class3
Explosion-proofNo
Degree of protection (IP)IP20
Release characteristicOther
Number of protected poles4
Width in number of modular spacings6
Concurrently switching neutral conductorNo
Pollution degree2
Power loss24.8W
Frequency0 - 0Hz
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Connectable conductor cross section solid-core0 - 70mm²
Connectable conductor cross section multi-wired0 - 50mm²
Rated impulse withstand voltage Uimp8kV
Additional equipment possibleYes
Ambient temperature during operating-25 - 60°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Flush-mounted installationNo
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated voltage-V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS864002R1597 | S804S-UCK63-R

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Rated current

63A

Voltage type

Other

Rated insulation voltage Ui

1500V

Current limiting class

3

Explosion-proof

Degree of protection (IP)

IP20

Release characteristic

Other

Number of protected poles

4

Width in number of modular spacings

6

Concurrently switching neutral conductor

Pollution degree

2

Power loss

24.8W

Frequency

0 .. 0Hz

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Connectable conductor cross section solid-core

0 .. 70mm²

Connectable conductor cross section multi-wired

0 .. 50mm²

Rated impulse withstand voltage Uimp

8kV

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Flush-mounted installation

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated voltage

-V

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.