Aleta.hr
Main Product Image

2CCS864017R0587 | S804U-K60

Code: 2002302

ManufacturerRAZNO
Catalog number2CCS864017R0587
Type
EAN code7612271214319

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

K

Built-in depth

82.5mm

Number of protected poles

4

Number of poles (total)

4

Rated insulation voltage Ui

690V

Rated voltage

-V

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated current

60A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Frequency

50 - 60Hz

Power loss

5.8W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated impulse withstand voltage Uimp

8kV

Over voltage category

3

Concurrently switching neutral conductor

No

Flush-mounted installation

No

Pollution degree

2

Additional equipment possible

Yes

Ambient temperature during operating

-25 - 60°C

Connectable conductor cross section solid-core

0 - 70mm²

Explosion-proof

No

Width in number of modular spacings

6

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 - 50mm²


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCS864017R0587 | S804U-K60

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

K

Built-in depth

82.5mm

Number of protected poles

4

Number of poles (total)

4

Rated insulation voltage Ui

690V

Rated voltage

-V

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated current

60A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Frequency

50 .. 60Hz

Power loss

5.8W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated impulse withstand voltage Uimp

8kV

Over voltage category

3

Concurrently switching neutral conductor

Flush-mounted installation

Pollution degree

2

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 70mm²

Explosion-proof

Width in number of modular spacings

6

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 .. 50mm²