Aleta.hr
Main Product Image

2CDS271337R0087 | SU201M-K0.2

Code: 2002345

ManufacturerABB
Catalog number2CDS271337R0087
EAN code4016779929967

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V11.2kA
Release characteristicK
Rated current0.2A
Rated voltage277V
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated insulation voltage Ui440V
Frequency50 - 60Hz
Number of protected poles1
Voltage typeAC/DC
Suitable for flush-mounted installationNo
Over voltage category3
Current limiting class3
Additional equipment possibleYes
Width in number of modular spacings1
Connectable conductor cross section multi-wired0 - 25mm²
Built-in depth69mm
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core0 - 35mm²
Pollution degree3
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271337R0087 | SU201M-K0.2

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

11.2kA

Release characteristic

K

Rated current

0.2A

Rated voltage

277V

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Number of protected poles

1

Voltage type

AC/DC

Suitable for flush-mounted installation

Over voltage category

3

Current limiting class

3

Additional equipment possible

Width in number of modular spacings

1

Connectable conductor cross section multi-wired

0 .. 25mm²

Built-in depth

69mm

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

0 .. 35mm²

Pollution degree

3

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.