Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Built-in depth69mm
Rated current15A
Rated voltage277V
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Number of protected poles1
Degree of protection (IP)IP20
Current limiting class3
Width in number of modular spacings1
Pollution degree3
Release characteristicC
Over voltage category3
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V11.2kA
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of poles (total)1
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 35mm²
Additional equipment possibleYes
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271337R0154 | SU201M-C15

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Built-in depth

69mm

Rated current

15A

Rated voltage

277V

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Number of protected poles

1

Degree of protection (IP)

IP20

Current limiting class

3

Width in number of modular spacings

1

Pollution degree

3

Release characteristic

C

Over voltage category

3

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

11.2kA

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of poles (total)

1

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

0 .. 35mm²

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.