Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated insulation voltage Ui440V
Frequency50 - 60Hz
Additional equipment possibleYes
Voltage typeAC/DC
Pollution degree3
Concurrently switching neutral conductorNo
Built-in depth69mm
Rated current15A
Width in number of modular spacings1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V11.2kA
Number of protected poles1
Ambient temperature during operating-25 - 55°C
Over voltage category3
Degree of protection (IP)IP20
Number of poles (total)1
Release characteristicC
Suitable for flush-mounted installationNo
Current limiting class3
Connectable conductor cross section solid-core0 - 35mm²
Rated voltage277V
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271337R0154 | SU201M-C15

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Professional worker

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Additional equipment possible

Voltage type

AC/DC

Pollution degree

3

Concurrently switching neutral conductor

Built-in depth

69mm

Rated current

15A

Width in number of modular spacings

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

11.2kA

Number of protected poles

1

Ambient temperature during operating

-25 .. 55°C

Over voltage category

3

Degree of protection (IP)

IP20

Number of poles (total)

1

Release characteristic

C

Suitable for flush-mounted installation

Current limiting class

3

Connectable conductor cross section solid-core

0 .. 35mm²

Rated voltage

277V

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.