Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Voltage typeAC/DC
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V11.2kA
Suitable for flush-mounted installationNo
Release characteristicC
Rated insulation voltage Ui440V
Frequency50 - 60Hz
Number of protected poles1
Current limiting class3
Pollution degree3
Built-in depth69mm
Width in number of modular spacings1
Rated voltage277V
Additional equipment possibleYes
Ambient temperature during operating-25 - 55°C
Over voltage category3
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0 - 25mm²
Connectable conductor cross section solid-core0 - 35mm²
Number of poles (total)1
Rated current30A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271337R0304 | SU201M-C30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Voltage type

AC/DC

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

11.2kA

Suitable for flush-mounted installation

Release characteristic

C

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Number of protected poles

1

Current limiting class

3

Pollution degree

3

Built-in depth

69mm

Width in number of modular spacings

1

Rated voltage

277V

Additional equipment possible

Ambient temperature during operating

-25 .. 55°C

Over voltage category

3

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 .. 25mm²

Connectable conductor cross section solid-core

0 .. 35mm²

Number of poles (total)

1

Rated current

30A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.