Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current25A
Rated voltage277V
Frequency50 - 60Hz
Built-in depth69mm
Voltage typeAC/DC
Rated insulation voltage Ui440V
Pollution degree3
Over voltage category3
Current limiting class3
Number of protected poles1
Degree of protection (IP)IP20
Width in number of modular spacings1
Release characteristicZ
Connectable conductor cross section solid-core0 - 35mm²
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Connectable conductor cross section multi-wired0 - 25mm²
Suitable for flush-mounted installationNo
Number of poles (total)1
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V11.2kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271337R0518 | SU201M-Z25

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

25A

Rated voltage

277V

Frequency

50 .. 60Hz

Built-in depth

69mm

Voltage type

AC/DC

Rated insulation voltage Ui

440V

Pollution degree

3

Over voltage category

3

Current limiting class

3

Number of protected poles

1

Degree of protection (IP)

IP20

Width in number of modular spacings

1

Release characteristic

Z

Connectable conductor cross section solid-core

0 .. 35mm²

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Connectable conductor cross section multi-wired

0 .. 25mm²

Suitable for flush-mounted installation

Number of poles (total)

1

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

11.2kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.