Aleta.hr
Main Product Image

2CDS271337R0538 | SU201M-Z32

Code: 2002393

ManufacturerABB
Catalog number2CDS271337R0538
EAN code4016779933018

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Release characteristicZ
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V11.2kA
Rated voltage277V
Suitable for flush-mounted installationNo
Rated insulation voltage Ui440V
Concurrently switching neutral conductorNo
Over voltage category3
Pollution degree3
Current limiting class3
Voltage typeAC/DC
Width in number of modular spacings1
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Built-in depth69mm
Frequency50 - 60Hz
Additional equipment possibleYes
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0 - 25mm²
Connectable conductor cross section solid-core0 - 35mm²
Number of protected poles1
Rated current32A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271337R0538 | SU201M-Z32

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Release characteristic

Z

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

11.2kA

Rated voltage

277V

Suitable for flush-mounted installation

Rated insulation voltage Ui

440V

Concurrently switching neutral conductor

Over voltage category

3

Pollution degree

3

Current limiting class

3

Voltage type

AC/DC

Width in number of modular spacings

1

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Built-in depth

69mm

Frequency

50 .. 60Hz

Additional equipment possible

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 .. 25mm²

Connectable conductor cross section solid-core

0 .. 35mm²

Number of protected poles

1

Rated current

32A