Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Built-in depth69mm
Over voltage category3
Pollution degree3
Frequency50 - 60Hz
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 25mm²
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core0 - 35mm²
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V11.2kA
Width in number of modular spacings1
Rated voltage277V
Rated insulation voltage Ui440V
Number of protected poles1
Concurrently switching neutral conductorNo
Release characteristicZ
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated current35A
Suitable for flush-mounted installationNo
Number of poles (total)1
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271337R0548 | SU201M-Z35

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Built-in depth

69mm

Over voltage category

3

Pollution degree

3

Frequency

50 .. 60Hz

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

0 .. 35mm²

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

11.2kA

Width in number of modular spacings

1

Rated voltage

277V

Rated insulation voltage Ui

440V

Number of protected poles

1

Concurrently switching neutral conductor

Release characteristic

Z

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated current

35A

Suitable for flush-mounted installation

Number of poles (total)

1

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Degree of protection (IP)

IP20