Technical specifications

Release characteristicB
Rated insulation voltage Ui440V
Frequency50 - 60Hz
Degree of protection (IP)IP20
Power loss1.8W
Explosion-proofNo
Over voltage category3
Current limiting class3
Voltage typeOther
Number of protected poles1
Concurrently switching neutral conductorNo
Width in number of modular spacings1.0
Built-in depth69mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Connectable conductor cross section solid-core0.75 - 35mm²
Rated current4A
Pollution degree3
Rated voltage230V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Flush-mounted installationNo
Additional equipment possibleYes
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-40 - 70°C
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271445R0045 | S201MT-B4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Degree of protection (IP)

IP20

Power loss

1.8W

Explosion-proof

Over voltage category

3

Current limiting class

3

Voltage type

Other

Number of protected poles

1

Concurrently switching neutral conductor

Width in number of modular spacings

1.0

Built-in depth

69mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated current

4A

Pollution degree

3

Rated voltage

230V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Flush-mounted installation

Additional equipment possible

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-40 .. 70°C

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA