Aleta.hr
Main Product Image

2CDS271445R0158 | S201MT-Z0,5

Code: 2002441

ManufacturerABB
Catalog number2CDS271445R0158
EAN code4016779127240

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Release characteristicZ
Rated current0.5A
Rated voltage230V
Voltage typeOther
Number of protected poles1
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Built-in depth69mm
Current limiting class3
Power loss2.4W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Flush-mounted installationNo
Ambient temperature during operating-40 - 70°C
Over voltage category3
Concurrently switching neutral conductorNo
Pollution degree3
Degree of protection (IP)IP20
Additional equipment possibleYes
Width in number of modular spacings1.0
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271445R0158 | S201MT-Z0,5

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Release characteristic

Z

Rated current

0.5A

Rated voltage

230V

Voltage type

Other

Number of protected poles

1

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Built-in depth

69mm

Current limiting class

3

Power loss

2.4W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Flush-mounted installation

Ambient temperature during operating

-40 .. 70°C

Over voltage category

3

Concurrently switching neutral conductor

Pollution degree

3

Degree of protection (IP)

IP20

Additional equipment possible

Width in number of modular spacings

1.0

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.