Number of poles (total)1
Rated voltage230V
Rated impulse withstand voltage Uimp4kV
Rated current40A
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Release characteristicC
Power loss4.8W
Frequency50 - 60Hz
Built-in depth69mm
Number of protected poles1
Voltage typeOther
Current limiting class3
Flush-mounted installationNo
Additional equipment possibleYes
Ambient temperature during operating-40 - 70°C
Explosion-proofNo
Over voltage category3
Pollution degree3
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Degree of protection (IP)IP20
Width in number of modular spacings1.0
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271445R0404 | S201MT-C40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

1

Rated voltage

230V

Rated impulse withstand voltage Uimp

4kV

Rated current

40A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Release characteristic

C

Power loss

4.8W

Frequency

50 .. 60Hz

Built-in depth

69mm

Number of protected poles

1

Voltage type

Other

Current limiting class

3

Flush-mounted installation

Additional equipment possible

Ambient temperature during operating

-40 .. 70°C

Explosion-proof

Over voltage category

3

Pollution degree

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Degree of protection (IP)

IP20

Width in number of modular spacings

1.0

Concurrently switching neutral conductor