Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency50 - 60Hz
Built-in depth69mm
Voltage typeOther
Rated voltage230V
Rated current10A
Pollution degree3
Over voltage category3
Current limiting class3
Number of protected poles1
Power loss4.2W
Degree of protection (IP)IP20
Rated insulation voltage Ui440V
Release characteristicB
Explosion-proofNo
Width in number of modular spacings2.0
Connectable conductor cross section solid-core0.75 - 35mm²
Concurrently switching neutral conductorYes
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-40 - 70°C
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271446R0105 | S201MT-B10NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Built-in depth

69mm

Voltage type

Other

Rated voltage

230V

Rated current

10A

Pollution degree

3

Over voltage category

3

Current limiting class

3

Number of protected poles

1

Power loss

4.2W

Degree of protection (IP)

IP20

Rated insulation voltage Ui

440V

Release characteristic

B

Explosion-proof

Width in number of modular spacings

2.0

Connectable conductor cross section solid-core

0.75 .. 35mm²

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-40 .. 70°C

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA