Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles1
Rated voltage230V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated current0.5A
Release characteristicK
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Built-in depth69mm
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Current limiting class3
Voltage typeOther
Rated insulation voltage Ui440V
Number of poles (total)2
Power loss2.2W
Flush-mounted installationNo
Additional equipment possibleYes
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
Pollution degree3
Degree of protection (IP)IP20
Concurrently switching neutral conductorYes
Ambient temperature during operating-40 - 70°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Width in number of modular spacings2.0
Over voltage category3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271446R0157 | S201MT-K0,5NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

1

Rated voltage

230V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated current

0.5A

Release characteristic

K

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Built-in depth

69mm

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Current limiting class

3

Voltage type

Other

Rated insulation voltage Ui

440V

Number of poles (total)

2

Power loss

2.2W

Flush-mounted installation

Additional equipment possible

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Pollution degree

3

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Width in number of modular spacings

2.0

Over voltage category

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.