Technical specifications

Release characteristicZ
Voltage typeOther
Built-in depth69mm
Frequency50 - 60Hz
Rated current0.5A
Rated voltage230V
Rated insulation voltage Ui440V
Over voltage category3
Current limiting class3
Concurrently switching neutral conductorYes
Number of protected poles1
Degree of protection (IP)IP20
Pollution degree3
Power loss4.8W
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
Width in number of modular spacings2.0
Ambient temperature during operating-40 - 70°C
Flush-mounted installationNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Additional equipment possibleYes
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271446R0158 | S201MT-Z0,5NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

Z

Voltage type

Other

Built-in depth

69mm

Frequency

50 .. 60Hz

Rated current

0.5A

Rated voltage

230V

Rated insulation voltage Ui

440V

Over voltage category

3

Current limiting class

3

Concurrently switching neutral conductor

Number of protected poles

1

Degree of protection (IP)

IP20

Pollution degree

3

Power loss

4.8W

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

Width in number of modular spacings

2.0

Ambient temperature during operating

-40 .. 70°C

Flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA