Aleta.hr
Main Product Image

2CDS271446R0277 | S201MT-K2NA

Code: 2002567

ManufacturerABB
Catalog number2CDS271446R0277
EAN code4016779126137

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui440V
Number of protected poles1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Frequency50 - 60Hz
Rated voltage230V
Built-in depth69mm
Power loss3.4W
Release characteristicK
Rated current2A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Current limiting class3
Voltage typeOther
Rated impulse withstand voltage Uimp4kV
Flush-mounted installationNo
Explosion-proofNo
Over voltage category3
Pollution degree3
Degree of protection (IP)IP20
Width in number of modular spacings2.0
Concurrently switching neutral conductorYes
Additional equipment possibleYes
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-40 - 70°C
Connectable conductor cross section solid-core0.75 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271446R0277 | S201MT-K2NA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

440V

Number of protected poles

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Frequency

50 .. 60Hz

Rated voltage

230V

Built-in depth

69mm

Power loss

3.4W

Release characteristic

K

Rated current

2A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Current limiting class

3

Voltage type

Other

Rated impulse withstand voltage Uimp

4kV

Flush-mounted installation

Explosion-proof

Over voltage category

3

Pollution degree

3

Degree of protection (IP)

IP20

Width in number of modular spacings

2.0

Concurrently switching neutral conductor

Additional equipment possible

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.