Aleta.hr
Main Product Image

2CDS271447R0135 | S201MTR-B13

Code: 2002640

ManufacturerABB
Catalog number2CDS271447R0135
EAN code4016779104234

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Number of poles (total)1
Release characteristicB
Number of protected poles1
Rated voltage253V
Rated current13A
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Power loss2.6W
Current limiting class3
Frequency50 - 60Hz
Flush-mounted installationNo
Pollution degree3
Over voltage category3
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-40 - 75°C
Additional equipment possibleYes
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0.75 - 35mm²
Width in number of modular spacings1.0
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271447R0135 | S201MTR-B13

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Number of poles (total)

1

Release characteristic

B

Number of protected poles

1

Rated voltage

253V

Rated current

13A

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Power loss

2.6W

Current limiting class

3

Frequency

50 .. 60Hz

Flush-mounted installation

Pollution degree

3

Over voltage category

3

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-40 .. 75°C

Additional equipment possible

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 .. 35mm²

Width in number of modular spacings

1.0

Explosion-proof