Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)1
Rated voltage253V
Release characteristicK
Number of protected poles1
Built-in depth69mm
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Rated current6A
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Current limiting class3
Power loss1.6W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Frequency50 - 60Hz
Connectable conductor cross section multi-wired0.75 - 25mm²
Over voltage category3
Explosion-proofNo
Pollution degree3
Width in number of modular spacings1.0
Concurrently switching neutral conductorNo
Ambient temperature during operating-40 - 75°C
Flush-mounted installationNo
Connectable conductor cross section solid-core0.75 - 35mm²
Degree of protection (IP)IP20
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271447R0377 | S201MTR-K6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

1

Rated voltage

253V

Release characteristic

K

Number of protected poles

1

Built-in depth

69mm

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated current

6A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Current limiting class

3

Power loss

1.6W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Frequency

50 .. 60Hz

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Over voltage category

3

Explosion-proof

Pollution degree

3

Width in number of modular spacings

1.0

Concurrently switching neutral conductor

Ambient temperature during operating

-40 .. 75°C

Flush-mounted installation

Connectable conductor cross section solid-core

0.75 .. 35mm²

Degree of protection (IP)

IP20

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.