  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency50 - 60Hz
Rated insulation voltage Ui440V
Pollution degree3
Current limiting class3
Voltage typeOther
Rated voltage253V
Built-in depth69mm
Rated current40A
Release characteristicB
Over voltage category3
Number of protected poles1
Explosion-proofNo
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Connectable conductor cross section solid-core0.75 - 35mm²
Additional equipment possibleYes
Connectable conductor cross section multi-wired0.75 - 25mm²
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Ambient temperature during operating-40 - 75°C
Rated impulse withstand voltage Uimp4kV
Flush-mounted installationNo
Width in number of modular spacings1.0
Power loss4W
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271447R0405 | S201MTR-B40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Pollution degree

3

Current limiting class

3

Voltage type

Other

Rated voltage

253V

Built-in depth

69mm

Rated current

40A

Release characteristic

B

Over voltage category

3

Number of protected poles

1

Explosion-proof

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Connectable conductor cross section solid-core

0.75 .. 35mm²

Additional equipment possible

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Ambient temperature during operating

-40 .. 75°C

Rated impulse withstand voltage Uimp

4kV

Flush-mounted installation

Width in number of modular spacings

1.0

Power loss

4W