Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Width in number of modular spacings1.0
Rated voltage253V
Release characteristicC
Rated current63A
Over voltage category3
Built-in depth69mm
Frequency50 - 60Hz
Power loss5.2W
Voltage typeOther
Pollution degree3
Explosion-proofNo
Rated insulation voltage Ui440V
Current limiting class3
Degree of protection (IP)IP20
Number of protected poles1
Concurrently switching neutral conductorNo
Ambient temperature during operating-40 - 75°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Connectable conductor cross section solid-core0.75 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated impulse withstand voltage Uimp4kV
Additional equipment possibleYes
Number of poles (total)1
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271447R0634 | S201MTR-C63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Width in number of modular spacings

1.0

Rated voltage

253V

Release characteristic

C

Rated current

63A

Over voltage category

3

Built-in depth

69mm

Frequency

50 .. 60Hz

Power loss

5.2W

Voltage type

Other

Pollution degree

3

Explosion-proof

Rated insulation voltage Ui

440V

Current limiting class

3

Degree of protection (IP)

IP20

Number of protected poles

1

Concurrently switching neutral conductor

Ambient temperature during operating

-40 .. 75°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated impulse withstand voltage Uimp

4kV

Additional equipment possible

Number of poles (total)

1

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.