Aleta.hr
Main Product Image

2CDS272280R0164 | S202CM-C16

Code: 2002767

ManufacturerABB
Catalog number2CDS272280R0164
EAN code4053546039443

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth70mm
Release characteristicC
Number of poles (total)2
Number of protected poles2
Rated current16A
Rated voltage240V
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Power loss4.2W
Frequency50 - 60Hz
Current limiting class3
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Over voltage category3
Pollution degree2
Additional equipment possibleYes
Width in number of modular spacings1
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired1 - 10mm²
Connectable conductor cross section solid-core1 - 16mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272280R0164 | S202CM-C16

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

70mm

Release characteristic

C

Number of poles (total)

2

Number of protected poles

2

Rated current

16A

Rated voltage

240V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Power loss

4.2W

Frequency

50 .. 60Hz

Current limiting class

3

Flush-mounted installation

Concurrently switching neutral conductor

Over voltage category

3

Pollution degree

2

Additional equipment possible

Width in number of modular spacings

1

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

1 .. 10mm²

Connectable conductor cross section solid-core

1 .. 16mm²

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.