Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicB
Frequency50 - 60Hz
Rated voltage240V
Built-in depth70mm
Rated current32A
Voltage typeOther
Number of poles (total)2
Flush-mounted installationNo
Number of protected poles2
Explosion-proofNo
Degree of protection (IP)IP20
Pollution degree2
Connectable conductor cross section multi-wired1 - 10mm²
Width in number of modular spacings1
Rated insulation voltage Ui500V
Power loss7.6W
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Connectable conductor cross section solid-core1 - 16mm²
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Current limiting class3
Over voltage category3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272280R0325 | S202CM-B32

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Frequency

50 .. 60Hz

Rated voltage

240V

Built-in depth

70mm

Rated current

32A

Voltage type

Other

Number of poles (total)

2

Flush-mounted installation

Number of protected poles

2

Explosion-proof

Degree of protection (IP)

IP20

Pollution degree

2

Connectable conductor cross section multi-wired

1 .. 10mm²

Width in number of modular spacings

1

Rated insulation voltage Ui

500V

Power loss

7.6W

Additional equipment possible

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Connectable conductor cross section solid-core

1 .. 16mm²

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Current limiting class

3

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.