Voltage typeAC/DC
Frequency50 - 60Hz
Built-in depth69mm
Rated current10A
Release characteristicC
Rated voltage440V
Pollution degree3
Width in number of modular spacings2
Current limiting class3
Over voltage category3
Rated insulation voltage Ui440V
Degree of protection (IP)IP20
Suitable for flush-mounted installationNo
Additional equipment possibleYes
Number of protected poles2
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated impulse withstand voltage Uimp4kV
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V11.2kA
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272337R0104 | SU202M-C10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Frequency

50 .. 60Hz

Built-in depth

69mm

Rated current

10A

Release characteristic

C

Rated voltage

440V

Pollution degree

3

Width in number of modular spacings

2

Current limiting class

3

Over voltage category

3

Rated insulation voltage Ui

440V

Degree of protection (IP)

IP20

Suitable for flush-mounted installation

Additional equipment possible

Number of protected poles

2

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

11.2kA

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA