Technical specifications

Rated voltage440V
Voltage typeAC/DC
Built-in depth69mm
Rated current35A
Frequency50 - 60Hz
Over voltage category3
Current limiting class3
Rated insulation voltage Ui440V
Release characteristicC
Degree of protection (IP)IP20
Width in number of modular spacings2
Pollution degree3
Additional equipment possibleYes
Suitable for flush-mounted installationNo
Number of protected poles2
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0 - 25mm²
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V11.2kA
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272337R0354 | SU202M-C35

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

440V

Voltage type

AC/DC

Built-in depth

69mm

Rated current

35A

Frequency

50 .. 60Hz

Over voltage category

3

Current limiting class

3

Rated insulation voltage Ui

440V

Release characteristic

C

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Pollution degree

3

Additional equipment possible

Suitable for flush-mounted installation

Number of protected poles

2

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0 .. 25mm²

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

11.2kA

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA