Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui440V
Rated voltage400V
Rated impulse withstand voltage Uimp4kV
Release characteristicK
Number of poles (total)2
Number of protected poles2
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Frequency50 - 60Hz
Power loss4.6W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Built-in depth69mm
Rated current13A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Current limiting class3
Width in number of modular spacings2.0
Additional equipment possibleYes
Ambient temperature during operating-25 - 55°C
Pollution degree3
Degree of protection (IP)IP20
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Connectable conductor cross section solid-core0.75 - 35mm²
Over voltage category3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272347R0447 | SU202MR-K13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Professional worker

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

440V

Rated voltage

400V

Rated impulse withstand voltage Uimp

4kV

Release characteristic

K

Number of poles (total)

2

Number of protected poles

2

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Frequency

50 .. 60Hz

Power loss

4.6W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Built-in depth

69mm

Rated current

13A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Current limiting class

3

Width in number of modular spacings

2.0

Additional equipment possible

Ambient temperature during operating

-25 .. 55°C

Pollution degree

3

Degree of protection (IP)

IP20

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Concurrently switching neutral conductor

Flush-mounted installation

Connectable conductor cross section solid-core

0.75 .. 35mm²

Over voltage category

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.