Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current30A
Voltage typeOther
Release characteristicK
Current limiting class3
Rated voltage400V
Width in number of modular spacings2.0
Frequency50 - 60Hz
Degree of protection (IP)IP20
Over voltage category3
Pollution degree3
Rated insulation voltage Ui440V
Explosion-proofNo
Power loss7W
Built-in depth69mm
Concurrently switching neutral conductorNo
Number of protected poles2
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
Flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Number of poles (total)2
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272347R0527 | SU202MR-K30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

30A

Voltage type

Other

Release characteristic

K

Current limiting class

3

Rated voltage

400V

Width in number of modular spacings

2.0

Frequency

50 .. 60Hz

Degree of protection (IP)

IP20

Over voltage category

3

Pollution degree

3

Rated insulation voltage Ui

440V

Explosion-proof

Power loss

7W

Built-in depth

69mm

Concurrently switching neutral conductor

Number of protected poles

2

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Number of poles (total)

2

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.