Aleta.hr
Main Product Image

2CDS272445R0354 | S202MT-C35

Code: 2002936

ManufacturerABB
Catalog number2CDS272445R0354
EAN code4016779123839

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)2
Release characteristicC
Number of protected poles2
Built-in depth69mm
Rated current35A
Rated insulation voltage Ui440V
Rated impulse withstand voltage Uimp4kV
Rated voltage400V
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Power loss-W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Over voltage category3
Flush-mounted installationNo
Width in number of modular spacings2.0
Pollution degree3
Additional equipment possibleYes
Degree of protection (IP)IP20
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-40 - 70°C
Connectable conductor cross section solid-core0.75 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272445R0354 | S202MT-C35

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Release characteristic

C

Number of protected poles

2

Built-in depth

69mm

Rated current

35A

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Rated voltage

400V

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Power loss

-W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Over voltage category

3

Flush-mounted installation

Width in number of modular spacings

2.0

Pollution degree

3

Additional equipment possible

Degree of protection (IP)

IP20

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.