Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Release characteristicK
Power loss2.6W
Explosion-proofNo
Concurrently switching neutral conductorNo
Frequency50 - 60Hz
Degree of protection (IP)IP20
Flush-mounted installationNo
Over voltage category3
Rated current5A
Rated voltage440V
Connectable conductor cross section solid-core0.75 - 35mm²
Pollution degree3
Voltage typeOther
Current limiting class3
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-40 - 70°C
Rated insulation voltage Ui440V
Number of protected poles2
Width in number of modular spacings2.0
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272445R0357 | S202MT-K5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Release characteristic

K

Power loss

2.6W

Explosion-proof

Concurrently switching neutral conductor

Frequency

50 .. 60Hz

Degree of protection (IP)

IP20

Flush-mounted installation

Over voltage category

3

Rated current

5A

Rated voltage

440V

Connectable conductor cross section solid-core

0.75 .. 35mm²

Pollution degree

3

Voltage type

Other

Current limiting class

3

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-40 .. 70°C

Rated insulation voltage Ui

440V

Number of protected poles

2

Width in number of modular spacings

2.0

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.