Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Rated current0.5A
Voltage typeOther
Rated voltage400V
Degree of protection (IP)IP20
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Over voltage category3
Current limiting class3
Power loss2.8W
Release characteristicD
Rated insulation voltage Ui440V
Width in number of modular spacings2.0
Number of protected poles2
Pollution degree3
Explosion-proofNo
Ambient temperature during operating-40 - 70°C
Connectable conductor cross section solid-core0.75 - 35mm²
Flush-mounted installationNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272445R0981 | S202MT-D0,5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated current

0.5A

Voltage type

Other

Rated voltage

400V

Degree of protection (IP)

IP20

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Over voltage category

3

Current limiting class

3

Power loss

2.8W

Release characteristic

D

Rated insulation voltage Ui

440V

Width in number of modular spacings

2.0

Number of protected poles

2

Pollution degree

3

Explosion-proof

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

Flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.