Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Concurrently switching neutral conductorNo
Frequency50 - 60Hz
Pollution degree3
Explosion-proofNo
Rated current10A
Over voltage category3
Power loss4.8W
Release characteristicB
Number of protected poles2
Width in number of modular spacings2.0
Current limiting class3
Rated insulation voltage Ui440V
Degree of protection (IP)IP20
Built-in depth69mm
Rated voltage440V
Voltage typeOther
Additional equipment possibleYes
Connectable conductor cross section solid-core0.75 - 35mm²
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Flush-mounted installationNo
Ambient temperature during operating-40 - 75°C
Number of poles (total)2
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272447R0105 | S202MTR-B10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Concurrently switching neutral conductor

Frequency

50 .. 60Hz

Pollution degree

3

Explosion-proof

Rated current

10A

Over voltage category

3

Power loss

4.8W

Release characteristic

B

Number of protected poles

2

Width in number of modular spacings

2.0

Current limiting class

3

Rated insulation voltage Ui

440V

Degree of protection (IP)

IP20

Built-in depth

69mm

Rated voltage

440V

Voltage type

Other

Additional equipment possible

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Flush-mounted installation

Ambient temperature during operating

-40 .. 75°C

Number of poles (total)

2

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA