Technical specifications

Voltage typeOther
Current limiting class3
Frequency50 - 60Hz
Pollution degree3
Width in number of modular spacings2.0
Built-in depth69mm
Rated voltage440V
Over voltage category3
Rated insulation voltage Ui440V
Rated current8A
Release characteristicZ
Power loss3.9W
Degree of protection (IP)IP20
Explosion-proofNo
Number of protected poles2
Connectable conductor cross section solid-core0.75 - 35mm²
Number of poles (total)2
Ambient temperature during operating-40 - 75°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Additional equipment possibleYes
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272447R0408 | S202MTR-Z8

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Current limiting class

3

Frequency

50 .. 60Hz

Pollution degree

3

Width in number of modular spacings

2.0

Built-in depth

69mm

Rated voltage

440V

Over voltage category

3

Rated insulation voltage Ui

440V

Rated current

8A

Release characteristic

Z

Power loss

3.9W

Degree of protection (IP)

IP20

Explosion-proof

Number of protected poles

2

Connectable conductor cross section solid-core

0.75 .. 35mm²

Number of poles (total)

2

Ambient temperature during operating

-40 .. 75°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.