Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Built-in depth69mm
Rated voltage440V
Power loss3.4W
Frequency50 - 60Hz
Degree of protection (IP)IP20
Current limiting class3
Rated insulation voltage Ui440V
Over voltage category3
Width in number of modular spacings2.0
Pollution degree3
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Additional equipment possibleYes
Number of protected poles2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Connectable conductor cross section solid-core0.75 - 35mm²
Flush-mounted installationNo
Explosion-proofNo
Ambient temperature during operating-40 - 75°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Rated current6A
Release characteristicC
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272565R0064 | S202MTR-C6 DC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Built-in depth

69mm

Rated voltage

440V

Power loss

3.4W

Frequency

50 .. 60Hz

Degree of protection (IP)

IP20

Current limiting class

3

Rated insulation voltage Ui

440V

Over voltage category

3

Width in number of modular spacings

2.0

Pollution degree

3

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Additional equipment possible

Number of protected poles

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Connectable conductor cross section solid-core

0.75 .. 35mm²

Flush-mounted installation

Explosion-proof

Ambient temperature during operating

-40 .. 75°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated current

6A

Release characteristic

C

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.